{"id":65936,"date":"2025-12-16T11:55:25","date_gmt":"2025-12-16T19:55:25","guid":{"rendered":"https:\/\/www.rambus.com\/?page_id=65936"},"modified":"2026-01-07T13:32:41","modified_gmt":"2026-01-07T21:32:41","slug":"flit","status":"publish","type":"page","link":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/","title":{"rendered":"FLIT (Flow Control Unit)"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"65936\" class=\"elementor elementor-65936\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b9c476a elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b9c476a\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-21ab565\" data-id=\"21ab565\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f42094d elementor-widget elementor-widget-breadcrumbs\" data-id=\"f42094d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"breadcrumbs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p id=\"breadcrumbs\"><span><span><a href=\"https:\/\/www.rambus.com\/\">Home<\/a><\/span><\/span><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-98117f2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"98117f2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2e5f609\" data-id=\"2e5f609\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-df938cd elementor-widget elementor-widget-heading\" data-id=\"df938cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">FLIT (Flow Control Unit)<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-04c3757 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"04c3757\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-cb6cf95 sticky-section-wrapper\" data-id=\"cb6cf95\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3f221fe sticky-section elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3f221fe\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-3aea679\" data-id=\"3aea679\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-792d9cf elementor-widget elementor-widget-text-editor\" data-id=\"792d9cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>Table of Contents<\/b><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51c3d22 elementor-widget elementor-widget-text-editor\" data-id=\"51c3d22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n \t<li><a href=\"#whatis\">Definition<\/a><\/li>\n \t<li><a href=\"#how\">How it Works<\/a><\/li>\n \t<li><a href=\"#features\">Features<\/a><\/li>\n \t<li><a href=\"#benefits\">Benefits<\/a><\/li>\n \t<li><a href=\"#enabling\">Enabling Technologies<\/a><\/li>\n \t<li><a href=\"#rambus\">Rambus Technologies<\/a><\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-ef36218 sticky-section-wrapper\" data-id=\"ef36218\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-413d21f section-family elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"413d21f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-a9bc5c0 product-table sticky-section\" data-id=\"a9bc5c0\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-982be2e elementor-widget elementor-widget-text-editor\" data-id=\"982be2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 id=\"whatis\">What is a FLIT?<\/h2><p>A FLIT (Flow Control Unit) is the smallest unit of data transmission in packet-switched networks, particularly in high-speed interconnect protocols like Compute Express Link (CXL) and PCI Express (PCIe). FLITs are fixed-size segments that encapsulate portions of a larger packet, enabling efficient and deterministic data flow across complex interconnect fabrics.<\/p><h2 id=\"how\">How FLIT works<\/h2><p>In modern interconnect architectures, data is transmitted in packets. These packets are broken down into FLITs to facilitate flow control, buffer management, and error detection. Each FLIT contains control information, payload data, and sometimes error-checking codes. The use of FLITs allows the system to manage congestion, prioritize traffic, and ensure reliable delivery even in multi-hop or multi-device environments.<\/p><p>For example, in CXL 3.0, FLITs are 256 bytes long and are used to carry memory and I\/O transactions between CPUs, accelerators, and memory expanders. The fixed size simplifies hardware design and improves predictability in latency-sensitive applications.<\/p><h2 id=\"features\">What are the key features of FEC?<\/h2><ul><li>Fixed-size data units (e.g., 256 bytes in CXL 3.0)<\/li><li>Used in layered protocol stacks (e.g., physical, data link, transaction layers)<\/li><li>Supports priority-based routing and traffic shaping<\/li><li>Compatible with advanced error correction (e.g., FEC, ECRC)<\/li><li>Enables multi-device and multi-host communication<\/li><\/ul><div>\u00a0<\/div><h2 id=\"benefits\">What are the benefits of FEC?<\/h2><ul><li><strong>Deterministic Latency:<\/strong> Fixed-size FLITs enable predictable timing and performance.<\/li><li><strong>Efficient Flow Control:<\/strong> Simplifies buffer allocation and congestion management.<\/li><li><strong>Scalable Communication:<\/strong> Supports high-throughput, low-latency data exchange across complex topologies.<\/li><li><strong>Enhanced Reliability:<\/strong> Facilitates error detection and recovery mechanisms.<\/li><\/ul><div>\u00a0<\/div><h2 id=\"enabling\">Enabling Technologies<\/h2><div><p>FLIT-based architectures are foundational in:<\/p><ul><li>CXL 2.0\/3.0 for memory pooling and coherent cache sharing<\/li><li>PCIe 6.0 with FLIT mode for high-speed data transfer<\/li><li>Network-on-Chip (NoC) designs in SoCs and data centers<\/li><li>High-performance computing (HPC) and AI\/ML accelerators<\/li><\/ul><\/div><div>\u00a0<\/div><h2 id=\"rambus\">Rambus Technologies<\/h2><p>Rambus offers CXL 2.0\/3.0 Interface IP and PCIe 6.0 Controller IP that support FLIT-based data transmission. These IP cores are designed for ultra-low latency and high bandwidth, making them ideal for next-generation data center, AI, and memory expansion applications. Rambus also integrates Forward Error Correction (FEC) and End-to-End CRC (ECRC) to ensure robust FLIT-level data integrity.<\/p><p>Click here to see L0p and Flit mode in action in PCIe 6.x <a href=\"https:\/\/www.rambus.com\/blogs\/revolutionizing-power-efficiency-in-pcie-6x-l0p-and-flit-mode-in-action\/\">here<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ac1fab elementor-widget elementor-widget-text-editor\" data-id=\"6ac1fab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"\/interface-ip\/glossary\/\">Back to Glossary<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>A FLIT (Flow Control Unit) is the smallest unit of data transmission in packet-switched networks, particularly in high-speed interconnect protocols like Compute Express Link (CXL) and PCI Express (PCIe). FLITs are fixed-size segments that encapsulate portions of a larger packet, enabling efficient and deterministic data flow across complex interconnect fabrics.<\/p>\n","protected":false},"author":6,"featured_media":61766,"parent":65763,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-full.php","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":"","_links_to":"","_links_to_target":""},"tags":[26430],"class_list":{"0":"post-65936","1":"page","2":"type-page","3":"status-publish","4":"has-post-thumbnail","6":"tag-glossary","7":"entry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.9 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FLIT (Flow Control Unit) | Glossary - Rambus<\/title>\n<meta name=\"description\" content=\"FLIT (Flow Control Unit) is a fixed-size data segment used in PCIe and CXL to enable efficient, reliable, and scalable high-speed data transmission.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FLIT (Flow Control Unit)\" \/>\n<meta property=\"og:description\" content=\"A FLIT (Flow Control Unit) is the smallest unit of data transmission in packet-switched networks, particularly in high-speed interconnect protocols like Compute Express Link (CXL) and PCI Express (PCIe). FLITs are fixed-size segments that encapsulate portions of a larger packet, enabling efficient and deterministic data flow across complex interconnect fabrics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/\" \/>\n<meta property=\"og:site_name\" content=\"Rambus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/RambusInc\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-07T21:32:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"286\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@rambusinc\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/\",\"url\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/\",\"name\":\"FLIT (Flow Control Unit) | Glossary - Rambus\",\"isPartOf\":{\"@id\":\"https:\/\/www.rambus.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg\",\"datePublished\":\"2025-12-16T19:55:25+00:00\",\"dateModified\":\"2026-01-07T21:32:41+00:00\",\"description\":\"FLIT (Flow Control Unit) is a fixed-size data segment used in PCIe and CXL to enable efficient, reliable, and scalable high-speed data transmission.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#primaryimage\",\"url\":\"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg\",\"contentUrl\":\"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg\",\"width\":500,\"height\":286,\"caption\":\"Data Center\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rambus.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Chip + Interface IP Glossary\",\"item\":\"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"FLIT (Flow Control Unit)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rambus.com\/#website\",\"url\":\"https:\/\/www.rambus.com\/\",\"name\":\"Rambus\",\"description\":\"At Rambus, we create cutting-edge semiconductor and IP products, providing industry-leading chips and silicon IP to make data faster and safer.\",\"publisher\":{\"@id\":\"https:\/\/www.rambus.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rambus.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rambus.com\/#organization\",\"name\":\"Rambus\",\"url\":\"https:\/\/www.rambus.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rambus.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rambus.com\/wp-content\/uploads\/2025\/09\/Rambus_Logo.png\",\"contentUrl\":\"https:\/\/www.rambus.com\/wp-content\/uploads\/2025\/09\/Rambus_Logo.png\",\"width\":200,\"height\":62,\"caption\":\"Rambus\"},\"image\":{\"@id\":\"https:\/\/www.rambus.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/RambusInc\",\"https:\/\/x.com\/rambusinc\",\"https:\/\/www.linkedin.com\/company\/rambus\",\"https:\/\/www.youtube.com\/user\/RambusWeb\"],\"description\":\"Rambus is a provider of industry-leading chips and silicon IP.\",\"email\":\"ebiz@rambus.com\",\"telephone\":\"+1-408-462-8000\",\"legalName\":\"Rambus Inc.\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"501\",\"maxValue\":\"1000\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FLIT (Flow Control Unit) | Glossary - Rambus","description":"FLIT (Flow Control Unit) is a fixed-size data segment used in PCIe and CXL to enable efficient, reliable, and scalable high-speed data transmission.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/","og_locale":"en_US","og_type":"article","og_title":"FLIT (Flow Control Unit)","og_description":"A FLIT (Flow Control Unit) is the smallest unit of data transmission in packet-switched networks, particularly in high-speed interconnect protocols like Compute Express Link (CXL) and PCI Express (PCIe). FLITs are fixed-size segments that encapsulate portions of a larger packet, enabling efficient and deterministic data flow across complex interconnect fabrics.","og_url":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/","og_site_name":"Rambus","article_publisher":"https:\/\/www.facebook.com\/RambusInc","article_modified_time":"2026-01-07T21:32:41+00:00","og_image":[{"width":500,"height":286,"url":"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@rambusinc","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/","url":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/","name":"FLIT (Flow Control Unit) | Glossary - Rambus","isPartOf":{"@id":"https:\/\/www.rambus.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#primaryimage"},"image":{"@id":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#primaryimage"},"thumbnailUrl":"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg","datePublished":"2025-12-16T19:55:25+00:00","dateModified":"2026-01-07T21:32:41+00:00","description":"FLIT (Flow Control Unit) is a fixed-size data segment used in PCIe and CXL to enable efficient, reliable, and scalable high-speed data transmission.","breadcrumb":{"@id":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#primaryimage","url":"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg","contentUrl":"https:\/\/www.rambus.com\/wp-content\/uploads\/2022\/08\/data-center-room.jpg","width":500,"height":286,"caption":"Data Center"},{"@type":"BreadcrumbList","@id":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/flit\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rambus.com\/"},{"@type":"ListItem","position":2,"name":"Chip + Interface IP Glossary","item":"https:\/\/www.rambus.com\/chip-interface-ip-glossary\/"},{"@type":"ListItem","position":3,"name":"FLIT (Flow Control Unit)"}]},{"@type":"WebSite","@id":"https:\/\/www.rambus.com\/#website","url":"https:\/\/www.rambus.com\/","name":"Rambus","description":"At Rambus, we create cutting-edge semiconductor and IP products, providing industry-leading chips and silicon IP to make data faster and safer.","publisher":{"@id":"https:\/\/www.rambus.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rambus.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rambus.com\/#organization","name":"Rambus","url":"https:\/\/www.rambus.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rambus.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.rambus.com\/wp-content\/uploads\/2025\/09\/Rambus_Logo.png","contentUrl":"https:\/\/www.rambus.com\/wp-content\/uploads\/2025\/09\/Rambus_Logo.png","width":200,"height":62,"caption":"Rambus"},"image":{"@id":"https:\/\/www.rambus.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/RambusInc","https:\/\/x.com\/rambusinc","https:\/\/www.linkedin.com\/company\/rambus","https:\/\/www.youtube.com\/user\/RambusWeb"],"description":"Rambus is a provider of industry-leading chips and silicon IP.","email":"ebiz@rambus.com","telephone":"+1-408-462-8000","legalName":"Rambus Inc.","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"501","maxValue":"1000"}}]}},"_links":{"self":[{"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/pages\/65936","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/comments?post=65936"}],"version-history":[{"count":0,"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/pages\/65936\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/pages\/65763"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/media\/61766"}],"wp:attachment":[{"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/media?parent=65936"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rambus.com\/wp-json\/wp\/v2\/tags?post=65936"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}